RT3

Heavy metals in. Clean water out.

Heavy metal treatment for anodizing, electroplating, metal finishing and etch lines. Captures copper, chromium, nickel, silver and gold to under 1 ppm, with zero hazardous sludge, ready for drain, evaporation or reuse.

RT3 heavy metal treatment system
<1ppmheavy metals in the treated effluent
RT3
8L/min with a 4-column crate
16 L/min avec SuperPac-8
5metals captured: Cu, Cr, Ni, Ag, Au
0 boues dangereuses
Comment ça marche

Treated on site,
start to finish.

Displaced wastewater collects in an effluent tank, the metals stay in the columns, and treated water goes to drain, evaporation or reuse. No chemicals, no sludge, no hauling.

RT3 connected to a SuperPac-8 crateSuperPac-8 column crateRT3 heavy metal treatment system, side profile
Collecter
2level sensors

Runs on tank level.

Displaced rinse water collects in a common effluent tank. A low-level sensor starts the RT3 only when there is enough to treat, and a high-level sensor raises an overflow alarm before anything spills.

Automatic start and stopOverflow alarm
Treat
<1ppm heavy metals

Metals stay in the columns.

Patented metallic-exchange media in the SuperPac columns captures copper, chromium, nickel, silver and gold. No chemicals are dosed at any point.

Cu · Cr · Ni · Ag · AuChemical-free
Décharger
0 boues dangereuses

Drain, evaporation or reuse.

Treated water leaves by gravity through 3/4″ piping, ready for drain, evaporation or reuse on the line. A pressure transducer and wet-tray leak sensors watch the columns the whole way.

Drain · evaporation · reuseLeak detection
Scales with flow. Start at 8 L/min with a 4-column crate, step up to SuperPac-8 for 16 L/min, and add crates as the line grows.
One system with RW3

Rinse control and treatment,
working as one.

Pair the RT3 with an RW3 and the line runs as one automated loop, from rinse tank to discharge-ready water. Rinse chemistry stays at setpoint, water goes in only when it is needed, and the effluent stays consistent.

01RW3

Sample

RW3 reads pH, conductivity and temperature in every rinse tank.

02RW3

Replenish

City or DI water goes to any tank that reads out of spec, then shuts off.

03Effluent tank

Capture

The displaced rinse water is pumped to a common effluent tank.

04RT3 + SuperPac

Treat

Metals are removed to under 1 ppm, with zero sludge, for drain, evaporation or reuse.

One loop instead of separate systems.

Conventional setup
RW3 + RT3
Rinse control
Fixed flow or periodic checks
Continuous monitoring, water on demand
Batch rinses
Full dump on a set schedule
A set volume exchanged until back in spec
Wastewater
A separate treatment step
Treated in the same loop, under 1 ppm, zero sludge
Empreinte
Separate systems to run
One integrated loop, rinse to discharge
Where it runs
Aerospace & defenseAnodizing, chem film, plating, etch
AutomotiveDecorative and functional plating
Electronics & PCBCopper plating, etch, gold finish
SemiconductorEtch, gold and copper plating
Medical devicesAnodizing, passivation, electropolish
Architectural aluminumAnodizing, etch
Jewelry & decorativeGold and silver plating
Job-shop finishersMixed lines, multiple metals
Caractéristiques

Compact. Automated.
Compliant.

20"W × 24"D × 60"H8–16 L/min<1 ppm effluentZero sludge
Candidature
Anodizing, electroplating, metal finishing and etch lines
Target metals
Copper, chromium, nickel, silver, gold
Effluent
Under 1 ppm heavy metals
Flow rate
8 L/min with a 4-column crate, 16 L/min with SuperPac-8
RT3 unit
20″W × 24″D × 60″H
SuperPac-8 crate
43″W × 26″D × 48″H
Décharger
By gravity through 3/4″ piping, to drain, evaporation or reuse
Sensors
Low and high level, pressure transducer, wet-tray leak detection
Scaling
Add crates or SuperPac columns as flow grows
Surveillance
Metatrax 24 heures sur 24, 7 jours sur 7, alertes par courriel, rapports d'activités
Produits chimiques et boues
Aucun dosage, zéro boue dangereuse
Installation
Typically 4–6 weeks from PO
Surveillance

Chaque système
surveillé 24 heures sur 24, 7 jours sur 7.

Every RT3 reports to Metatrax. It tracks flow and column pressure, flags leaks and overflows, and emails your team with troubleshooting steps.

  • 24/7 monitoring Flow and column pressure
  • Leak and overflow alerts Email, with troubleshooting steps
  • Column changes Planned, not reactive
  • Rapports d'activité prêts à l'exportation
metatrax.com
Rapport de production standard
GAL LAujourd'huiExporter en format PDF
Jour de traitement moyen
89,8 gal/jour
Actif 1 sur 1 jour

Gallons
Division totale traitée
90GAL
Total cumulé (dernières 24 heures)

Minutes actives enregistrées
340MIN
Temps de disponibilité totale active

Pression du filtre
Pression de la pompe A par rapport à la pression de la pompe B

Pompe A PSI Pompe B PSI
Next step

Start with a site assessment.

We size the system around your line.

01

Share line details

Tank count, running or batch rinses, flow rates and metals.

02

Site and space review

Footprint, access and utilities.

03

Sizing and proposal

RW3 units, RT3 crates and SuperPac columns.

04

Installation

Typically 4–6 weeks from PO.

Coordonnées

Let’s talk about
your wastewater.

+1 (514) 633-8663 Téléphone
1925 46e Avenue, Lachine, QC Siège social et fabrication